Out stock

CENTECH Surge Protector- 385V Type 2-2+3 poles- 230V IT/TT

SKU: CV057677

AVAILABILITY: In stock

VENDOR: CENTECH

999 kr
799 kr eks. mva.
Only 1.000 kr away from free shipping

Product Information


CENTECH logo - Elbilgrossisten
  • Especially Adapted for 230V IT/TT net
  • Surge protection type 2 (intermediate protection)
  • For installations with/ without distributed earth and with signal contact
  • No requirement for additional protection (ground fault circuit breaker/non- flammable enclosure)


Overspenningsvern TT-nett IT-nett 230V 3-fas 1-fas 

 

Surge protection (etc.) from CENTECH can be used in all types of installations for the distribution of power. It is intended for mounting on a DIN- Rail and fits under a modular cover. Type 2+3 surge protector is especially developed for protection against overvoltage in low-voltage systems. Most have replaceable protection modules. Enclosures are halogen-free. Manufactured from flame retardant PBT or fire resistant nylon (depending on the model). All terminals are made of copper, if it should be connected with aluminum, transitions must be used.

The surge protector is supplied (internally) with a signal contact for indicating the fuse. 

Can be used on installations with or without distributed soil.

 

From 1 January 2019, a surge protector is a legally required protection in the fuse box when installing a new current course to the charging of electrical vehicles. This applies both to a new charging point or charging station.
                                                                                                    

According to regulations on electrical equipment §21, we are obliged to inform our customers that all electrical equipment intended to be part of a fixed electrical installation can only be installed by authorized and registered installation company installasjonsvirksomhet.

 

 

 

Technical Details


Area of Use Indoors in fuse box
Power Grid IT / TT
Rated Voltage 385V (AC) / 505 (DC)
Number of Poles 2- and 3-poles
Type 2+3 (Intermediate protection)
Nominal Discharge Impulse Current (8/20) Imax  20 kA
Maximum Arrester Surge Current (8/20) Imax 40kA
Security Level/ Up @ In  <2.0kV
Reaction Time ≤100 ns
Follow Current/ Leakage Current No
Largest Pre-Connected Fuse 125A
Overvoltage Resistance 700V/120min
Operating Temperature - 40ºC - + 80ºC
Conductor Cross Section Single core 4-35mm².
Multi-wired with end sleeve 4-25mm²
Operating Temperature -30°C to +50°C
Installing 35mm DIN, according to EN 50022/DIN46277-3
Enclosure Material Thermoplastic, UL94 V-0. Self-extinguishing.
Protection Class (IP) IP20
Installation Width 2 modules, DIN 43880
Thermal Disconnect (internal solder fuse) Indication flag window: 
Green = normal, Red = fault, replace plug.
Signal Contact Yes
Signal Contact Type Potential-free contact set NO/NC
Nominal Voltage/Current Out/In AC: 250V/0.5A
DC: 250V/0.1A; 125V/0.2A; 75V/0.5A
Largest Cross-Section Signal Contact
Max 1.5 mm² (or # 16AWG)
Sales Packaging 1 pc
Volume 0,194 dm³ (2-poles)
0,292 dm³ (3-poles)
Packaging Measurements 90 x 36 x 60 mm (2-poles)
90 x 54 x 60 mm (3-poles)
Weight 100g (2-poles)
130g (3-poles)
Standards and Approval
IEC61643-11:2011; UL1449 4th
Warranty 2 years

 

Questions and Answers


Do I have to have surge protection?

NEK 400:2018, part standard 722 supply of electrical vehicles states the following:
It is now required that the protection point must be protected by a surge protector. This can preferably be a surge protector that stands in front of the entire installation.

The reason being is that there is a greater increase in the number of rechargeable cars that have been destroyed as a result of lightning surges or connection surges. The repair costs can reach several hundred thousand kroner and it is not certain that this is covered by insurance. It is recommended to interrupt and disconnect the charging equipment during thunderstorms.


 

Warranty


We are proud of our products and it is important for us that you, as a customer, are satisfied. That's why we give you a 2 year warranty on the vast majority of our products- with the exception of consumer goods.  Look for the warranty logo to see what applies to this particular product. Our warranty means that this product should function as expected through it's entire warranty time. (In addition to your rights under the Consumer Goods Act). Read more about this warranty in our purchase conditions kjøpsbetingelser.


 

 