Product Information
- Fits on DIN-Rails
- Can be used on current courses up to 63A - Trigger current: 30 mA
- Works on all power grids-230V 1/3-phase (IT) and 400V 3-phase (TN)
- Fulfills requirements for charging electrical vehicles (NEK 400:2014 §722.531.2)
CHiNT earth fault circuit breaker/ earth fault protection meets the requirements of NEK 400:2014 §722.531.2. Interpretation indicates that current controlled earth fault protection type B must be used on new current courses that will be used for charging electric cars or plug-in hybrids. This earth fault circuit breaker works excellently as protection in new installations. CHiNT earth-fault circuit breakers type B have been specially developed to provide correct tripping in the case of pulsating or smooth direct current (DC).
B-type earth-fault circuit breaker is required on all new current courses intended for charging electric vehicles installed after 1.1.2015. These can either be integrated into the charging station or mounted in the fuse box.
CHiNT NL210 earth-fault circuit breaker fits all mains and current courses up to 63A. This applies for both 1-phase and 3-phase 230V (IT/TT), as well as 3-phase 400V (TN). Note that this is a 2-pole RCD type B (3-module) which supports only 1-phase and takes up less space.
According to regulations on electrical equipment §13, we are obliged to inform our customers that all electrical equipment intended to be part of a fixed electrical installation can only be installed by an authorized and registered installation company installasjonsvirksomhet.
Technical Details
Earth-Fault Circuit Breaker |
Type B |
---|---|
Number of Amps |
Up to 63A |
Voltage |
230V \ 400V |
Number of Poles |
4 |
Width (DIN- Rail) | 4 module |
Trigger Current |
30 mA |
Operating Temperature |
-25°C - 45°C |
Measurements | H 86mm x W 72mm x D 79mm |
Weight | 464 grams |
Origin | China |
Security/ Protection Class | IP20 |
Installation | performed by an authorized electrician |
Certifications |
CE, KEMA |
Warranty |
2 years |
Questions and Answers
How should the earth-fault circuit breaker be installed in the 230V/ IT network?
To make the test button work on IT mains (normal 230V) the following poles must be used:1) 230V / 1-phase: N + 1 (top side) and N + 2 (bottom side)
2) 230V/ 3-phase: N+1+3 (top side) and N+2+4 (lower side)
3) 400V / 3-phase: N+1+3+5 (top side) and N+2+4+6 (lower side)- It is important that N is on the far left.
Warranty
We are proud of our products and it is important for us that you, as a customer, are satisfied. That's why we give you a 2 year warranty on the vast majority of our products- with the exception of consumer goods. Look for the warranty logo to see what applies to this particular product. Our warranty means that this product should function as expected through it's entire warranty time. (In addition to your rights under the Consumer Goods Act). Read more about this warranty in our purchase conditions kjøpsbetingelser.
Related Products
SKU: WPCTM3G2
AVAILABILITY: In stock
PRODUCT TYPE: Wireless charger for Tesla Model 3
VENDOR: Elbilgrossisten
Product Information Product Information Charge your mobile phone vertically or horizontally- perfect for larger telephones. Charge two mobile telephones at once with up to 10W Cable with USB Type C plug — Provides the option of charging with a cable if...
1.118 kr eks. mva.
SKU: CV067300
AVAILABILITY: In stock
PRODUCT TYPE: Surge protection
VENDOR: CENTECH
Product Information Product Information Especially Adapted for 400V TN-grid Surge Protection Type 2 (intermediate protection) Installs on a DIN-Rail Especially developed against overvoltage in low voltage systems Surge protection (etc.) from CENTECH can be used in all types...
639 kr eks. mva.
SKU: CV057677
AVAILABILITY: In stock
PRODUCT TYPE: Surge protection
VENDOR: CENTECH
Product Information Product Information Especially Adapted for 230V IT/TT net Surge protection type 2 (intermediate protection) For installations with/ without distributed earth and with signal contact No requirement for additional protection (ground fault circuit breaker/non- flammable enclosure) Surge protection (etc.) from...
799 kr eks. mva.
SKU: EH22CB
AVAILABILITY: In stock
PRODUCT TYPE: Charging stations
VENDOR: Easee
Product Information Product Information Easee Charge charging unit- Charging unit only (Charge berry) Simply clicks onto the back plate Meant for home charging and smaller charging facility (max 3 pcs per course) Supports all power grids (IT, 230V/1+3-Phase, TT and TN 400V) and all...
6.392 kr eks. mva.
SKU: EHGUM
AVAILABILITY: In stock
PRODUCT TYPE: Accessories
VENDOR: Easee
Product Information Product Information Rubber Cover for type 2 plug Easy to disassemble/ assemble Protects plug against dust and dirt Soft and flexible rubber Rubber cover to your Easee Home and Charge. According to regulations on electrical equipment §21,...
135 kr eks. mva.